Ensuring Asset Integrity Post-Fire: Horizontal Drum Vessel Inspection
All ProjectsCase Study

Ensuring Asset Integrity Post-Fire: Horizontal Drum Vessel Inspection

Following a fire incident, TechCorr performed a comprehensive external API 510 compliance inspection of a 60-inch-diameter horizontal drum, using ultrasonic thickness measurements at selected Condition Monitoring Locations to confirm a low 0.5 MPY corrosion rate and preserved metallurgical integrity, and to guide targeted recoating and maintenance recommendations.

Following a fire incident, TechCorr performed a comprehensive external API 510 compliance inspection of a 60-inch-diameter horizontal drum, using ultrasonic thickness measurements at selected Condition Monitoring Locations to confirm a low 0.5 MPY corrosion rate and preserved metallurgical integrity, and to guide targeted recoating and maintenance recommendations.

Discuss a similar project with our team

Our NDT and asset integrity specialists can help you apply these insights to your facilities. Request a quote and our team will respond within one business day.

Cookie & Privacy Preferences

We use cookies to keep the site working, understand which pages you visit, and improve our outreach. Essential cookies are always on. You can accept all or choose which to enable. Details are in our Privacy Policy.